IAI America XSEL-S User Manual
Page 35

4.
Appendix
29
Monitor LED
Contents
Cause and Remedy
EE69
EE6C
24V I/O Error
DO Output Current Error
It is generated when the +24V power for I/O is not
supplied. Check the power supply.
(How to start up the controller without connecting
the I/O 24V power)
Set the I/O parameter No.10 to 13 corresponding
to the standard or extended I/O board to “0”. (Note)
I/O cannot be used.
ED5D
Fieldbus Error
This occurs when the network connection is not
established.
Check the parameters on XSEL and the
parameters on PLC.
(Way to boot the controller without connecting to
EtherCAT®)
Set both the I/O parameter No.18 to “0”.
�
Other Alarm Codes Related to EtherCAT®
� Message Level Error
No.
Error name
Contents / Counteractions
A6B
Fieldbus Error
(FBRS Link Error)
FBRS Link Error was detected.