beautypg.com

B. leveling – HTP ELP-199 User Manual

Page 12

background image

12

LP-294 REV. 2.20.14

This boiler is certified for indoor installations only. Do not install the boiler outdoors. Failure to install this boiler indoors could result in
substantial property damage, severe personal injury, or death.

2. Check for nearby connections to:

System water piping

Venting connections

Gas supply piping

Electrical power

Condensate drain


3. Check area around boiler. Remove any combustible materials,
gasoline, and other flammable liquids.

Failure to keep boiler area clear and free of combustible materials,
liquids, and vapors can result in substantial property damage,
severe personal injury, or death.

4. Gas control system components must be protected from dripping water
during operation and service.

5. If the boiler is to replace an existing boiler, check for and correct any
existing system problems, such as:

System leaks

Location that could cause the system and boiler to freeze and
leak.

Incorrectly-sized expansion tank


6. Clean and flush system when reinstalling a boiler.

NOTE: When installing in a zero clearance location, it may not be possible
to read or view some product labeling. It is recommended to make note of
the boiler model and serial number.

Do not mount the boiler to a hollow wall. Mount to the studs only.
Failure to do so will result in substantial property damage, and could
result in severe personal injury or death.

Use extreme care not to drop the boiler or cause bodily injury while
lifting or mounting the boiler onto the optional wall mount bracket.
Failure to do so will result in property damage, and could result in
severe personal injury or death.

B. LEVELING







In order for the condensate to properly flow out of the collection
system, the area where you locate the boiler must be level. The
boiler comes equipped with leveling feet. Should you find the floor
beneath the boiler is uneven, adjust the leveling feet with a wrench.

Figure 1

– Leveling

Figure 2

– Recommended Service Clearances