beautypg.com

Securitron iMXDa_iEXDa_CH INSTALLATION User Manual

Page 15

background image

P/N 500-22155

Page 15

Rev. A, 11/12

8. MAGNALOCK MAINTENANCE
Visual Inspection

 Check the rubber washers for elasticity and proper pivoting. Tighten as required.

 Check for build-up of debris on the magnet face and strike armature. Clean as required.

 Check for rust on the magnet and strike plate armature. Clean as required.

 Check for iron debris on the actuator and strike (DPS) magnetic housings. Remove debris

as required.

Cleaning Methods

 Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and

strike plate armature.

 Cleaning once a year is recommended.

 Clean every six months where minor rusting occurs.

 Clean every three months if rust conditions are severe.

 Use a plastic dishwashing scrub pad to aid in the removal of rust.

DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING

DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER


9. MAGNACARE

LIFETIME REPLACEMENT WARRANTY

For warranty information visit

www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/


PATENTS

The Securitron iMXDa is listed under U.S. patent #6,609,738 and 5,758,913.

Additional patents pending.