Securitron iMXDa_iEXDa_CH INSTALLATION User Manual
Page 15
P/N 500-22155
Page 15
Rev. A, 11/12
8. MAGNALOCK MAINTENANCE
Visual Inspection
Check the rubber washers for elasticity and proper pivoting. Tighten as required.
Check for build-up of debris on the magnet face and strike armature. Clean as required.
Check for rust on the magnet and strike plate armature. Clean as required.
Check for iron debris on the actuator and strike (DPS) magnetic housings. Remove debris
as required.
Cleaning Methods
Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and
strike plate armature.
Cleaning once a year is recommended.
Clean every six months where minor rusting occurs.
Clean every three months if rust conditions are severe.
Use a plastic dishwashing scrub pad to aid in the removal of rust.
DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING
DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER
9. MAGNACARE
LIFETIME REPLACEMENT WARRANTY
For warranty information visit
www.securitron.com/en/site/securitron/About/MagnaCare-Warranty/
PATENTS
The Securitron iMXDa is listed under U.S. patent #6,609,738 and 5,758,913.