Serial command directory for intera and maestro, Command name command description – Gentec-EO PC-Gentec-EO (for MAESTRO and INTEGRA) User Manual
Page 43

PC-Gentec-
EO User’s Manual Revision 5.0
42
8.1.3
Serial Command Directory for Intera and Maestro
Command name
Command Description
DISPLAY COMMANDS
Set Range
SCS
Manually set range.
Set Range Up
SSU
Change scale to the next higher range.
Set Range Down
SSD
Change scale to the next lower range.
Get Current Range Index
GCR
Returns scale index between 0 to 41
Get Autoscale
GAS
Returns autoscale status
Display Valid Scale
DVS
Displays the valid ranges for the connected detector head.
Set trigger level
STL
Set the internal trigger level when measuring pulse energy.
Get Trigger Level
GTL
Returns trigger level value
Get Mode Display
GMD
Returns the current display mode on MAESTRO
MEASUREMENT COMMANDS
MEASUREMENT DATA ACQUISITION
Query Current Value
CVU
Get the value currently displayed on the screen.
Download points
CAU
Send the values in ASCII to the serial port with the data sampling
setting.
Stop the CAU Command
CSU
Stop the CAU Command.
Query New Value Ready
NVU
Determine if new reading is available.
Set the autoscale
SAS
Set the autoscale.
Get the laser rep rate frequency
GRR
Send the value in ASCII to the serial port.
Set the joulemeter binary mode
SS1
Set the joulemeter binary mode or ASCII mode
Get Binary Joulemeter Mode
GBM
Returns binary joulemeter mode or ASCII mode
Set Analog Output
ANO
Enables or disables analog output
MEASUREMENT SETUP
Set Personal Wavelength Correction PWC
Specify the wavelength.
Get Wavelength
GWL
Returns wavelength in nm
MEASUREMENT CONTROL
Set Anticipation
ANT
Turn anticipation on or off.
Get Anticipation status
GAN
Returns the anticipation status
Set Zero Offset
SOU
Zero the reading.
Clear Zero Offset
COU
Undo the zeroing of the reading.
Get Zero Offset
GZO
Returns zero offset status
Set diode Zero Offset
SDZ
Zero the reading for all scale’s for the photodiode.
Set User Multiplier
MUL
Set the value of the multiplier’s correction value.
Get User Multiplier
GUM
Returns the current multiplier’s correction value
Set User Offset
OFF
Set the value of the Offset correction value.
Get User Offset
GUO
Returns the current offset correction value
SET Single shot Energy mode
SSE
Set the Energy mode for the calorimeter mode.
Set attenuator
ATT
Set the attenuator.
Get Attenuator
GAT
Returns the attenuator status
INSTRUMENT AND DETECTOR INFORMATION COMMANDS
Query version
VER
Get firmware version of the monitor.
Query Status
STS
Retrieve detector information and monitor settings.
Query Extended Status
ST2
Returns extended status