5. Raise the bucket evenly from below the horizontal level. The
remaining load in the bucket is weighed, and the weight of the load
delivered to the truck is displayed in the Load-field.
Note! The weight of the remaining load must be equal or greater than
the Min Load specified in Parameter Setup I.
Repeat the procedure until the correct weight has been shaked off to the
truck.
3.9 Cancelling/Dumping last Bucket
The operator can easily cancel the last weighing if the load in the bucket has
been dumped back to the material bank:
x
Empty the bucket. Press and hold Cancel/* for at least 1 second.
Note: The weight is subtracted from the total weight.
3.10 Pause mode
LOADTRONIC 3 can be set in pause mode when the machine performs
actions that are not to be recorded, e.g. tidying the work place.
Pause is selected by:
1. Pressing the up-arrow/
n
from automatic weighing mode. When the
LOADTRONIC 3 is in the pause mode no buckets will be weighed or
recorded. The display will show a row of ‘–‘ signs, refer Figure 3-12.
The pause mode is ended by:
2. Pressing up-arrow/
n
(in pause mode). The LOADTRONIC 3 returns to
automatic weighing.