beautypg.com

Fairbanks scales – Fairbanks LoadTronic 3 - Loader Weighing System User Manual

Page 26

background image

page 26

Procedure to adjust the material in the bucket:

1. Press and hold * for at least 1 second to cancel the bucket weight from

the running total weight. The current approximate weight is shown in
the display.

2. Move the machine to a place where the surplus material can be

dumped.

3. Shake off the material until the display shows the approximate desired

weight.
Note: The weight shown is slightly different from the actual weight,
since the bucket is not tilted rearward.

4. Retract the bucket and lower the arm when complete.
5. Press # or move the gear selector to forward drive and then back to

reverse to initiate the weighing. The machine does not have to be
moved.

6. Raise the bucket evenly from below the horizontal level. The load is

now re-weighed.

3.8 Shakeoff to Truck

If shakeoff to truck has been set in Parameter Setup II, refer Figure 3-6, the
operator can shake off part of the load onto the truck; the material delivered
to the truck is added to the running total.

Procedure for shakeoff to truck:

1. Press and hold * for at least 1 second to cancel the bucket weight from

the running total weight. The current weight of the material delivered
to the truck is 0 kg.

2. Shake off material until the display shows the approximate desired

weight delivered to the truck.
Note: The weight shown is slightly different from the actual weight,
since the bucket is not tilted rearward.

3. Retract the bucket and lower the arm when complete.
4. Press # or move the gear selector to forward drive and then back to

reverse to initiate the weighing. The machine does not have to be
moved.

Fairbanks Scales