Embedded Check Post
Slotted Holes
Welded Bumper
Bolted Shims
LATERAL
LONGITUDINAL
CHECKING
CHECKING
Adjust here
Adjust here
50614_20
The Check Brackets are designed to limit and restrict the Scale Modules movement for 360
degrees. When they are properly adjusted, they will limit any movement from a minimum of
1/16" to a maximum of 1/8".
Each Check Bracket is provided with slotted mounting holes that are three (3) inches long. To
adjust lateral checking (side to side), slide the entire check bracket sideways and retighten.
To adjust longitudinal checking (end to end) install or remove three (3) different sized shims,
and retighten the two securing bolts.
ADJUST CHECKING
1/16" Min to 1/8" Max
LONGITUDINAL
LATERAL
50614_21
6: Place wooden blocking and cribbing material suitable for supporting each module into
position near each pier and grout plate. Each section will require four points of support,
therefore arrange the placement of these supports accordingly. It is recommended to set
blocking to support the module 1 to 2 inches higher (than the certified prints indicate its final
elevation should be) at this time.
7: With a crane and rigging (4 leg drop) of suitable capacity, install each module onto the
supporting blocking.
Note: On pit installations, remove the access panels on the module(s) before setting.