Fairbanks 2000 SERIES Rocker Column Railroad Scale User Manual
Page 20
03/10
20
50614 Rev. 5
2-I: Grout plate assemblies:
Caution: Base plates weigh approximately 180 lb.. apiece. Work Safely.
Grout Plates
50614_16
1: Clean the top of the piers thoroughly, and ensure they are free of any oil or grease
deposits. Clean the threads of all base plate pier bolts with a wire brush, using a thread file
to restore any damaged threads. Lightly oil the threads, and ensure the threads are clean
and in good condition by running a threaded nut down and up the threads of the bolt.
Remove all nuts from the pier bolts.
2: Place several short lengths of wooden 2 X 4's or 4 X 4's in the center of the pier bolts.
4
2
3
Towards
End Wall
Center
of Scale
1
1
1
2
2
2
50614_17
ABOVE: End Grout Plate
1 = Leveling Screws
2 = Pier Bolt Mounting Holes
3 = Approach Rail Column Bolts (1-8" bolts)
4 = Load Cell Base Plate Bolts (3/4-10" bolts)
3: Per the Certified Prints, identify and locate each Grout Plate. Noting the correct orienta-
tion, place the Grout Plate onto the wooden blocking on the pier, guiding the 4 pier bolts into
the 4 corner holes of the grout plate.
NOTE: Double Module (25') Scales are three (3) Section Scales that use six (6) Grout
Plates. The Center Section Grout Plates are arranged differently than the ends. Locate
and install these plates per the Certified Print.