Alliance Laundry Systems UF35PV User Manual
Page 79
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
77
F232059
NOTE: The cycle shown is intended for setup of
supplies with a 5-supply system. If the machine is
equipped with 8 supplies, refer to Programming a
Supply Step – Models with 8 Supplies. As extra
supplies are normally controlled by bank 2,
program supplies 6, 7, 8, and 9.
Cycle 38
Formulas Common to All Markets
(ReWash/reclaim)
Step
Description
Min:sec
1
130°F (54°C) Fill to High Level
5:00
2
Wash 1
2:00
3
Drain 1
1:00
4
Hot Fill to Low Level
5:00
5
Supply 1 and 2 (Display: “SA”)
0:45
6
Wash 1
4:00
7
Drain 1
1:00
8
Hot Fill to Low Level
5:00
9
Supply 1 and 2 (Display: “SA”)
0:45
10
Wash 1
7:00
11
Drain 1
1:00
12
Hot Fill to High Level
5:00
13
Wash 1
4:00
14
Drain 1
1:00
15
Medium Spin
1:00
16
Warm Fill to Low Level
5:00
17
Wash 1
2:00
18
Drain 1
1:00
19
110°F (43°C) Fill to High Level
5:00
20
Wash 1
2:00
21
Drain 1
1:00
22
110°F (43°C) Fill to Low Level
5:00
23
Supply 3 and 4 (Display: “SI”)
0:30
24
Wash 1
4:00
25
Drain 1
1:00
26
High Spin 3 (SDLY 0:45)
4:00
Cycle 39
Formulas Common to All Markets
(Chemical Supply Setup)
Step
Description
Min:sec
1
Warm Fill to Low Level
5:00
2
Supply 1
2:00
3
Supply 2
2:00
4
Supply 3
2:00
5
Supply 4
2:00
6
Supply 5
2:00
7
Wash 1
0:30
8
Drain 1
1:00