Operation
17
F232059
Table 1 (Continued)
Display Interpretations
Display
Meaning
Display
Meaning
STOP
Stop button pressed or cycle ended
WE-6 Prompts
S1
Supply #1 (Detergent)
°FAR
Temperature in degrees Fahrenheit
S2
Supply #2 (Bleach)
°CEN
Temperature in degrees Centigrade
S3
Supply #3 (Sour)
1DRAIN
One drain capability selected. (This means
that a second independent drain controlled by
Auxiliary 2 output is disabled.)
S4
Supply #4 (Softener)
2DRAIN
Second independent drain enabled (via
Auxiliary 2 output – precludes control of
recirculation pump via Auxiliary 2, if
selected). This should not be confused with
the “dual drain” option.
S5
Supply #5 (Starch/Sizing)
TH
Controlled temperature fill to high level
TM
Controlled temperature fill to medium level
TL
Controlled temperature fill to low level
ADV
Advance (skip steps) feature enabled
TO
Controlled temperature overflow
NO ADV
Advance feature disabled
WH
Warm fill to high level
MANUAL
Manual Mode enabled
WM
Warm fill to medium level
NO MAN
Manual Mode disabled
WL
Warm fill to low level
WET CL
Wet clean function for Auxiliary 1 output
(1/2 wash speed) and Auxiliary 2 output
(recirculation pump) enabled. (Refer to
“2DRAIN”.)
WO
Warm fill to overflow level
W1
Wash 1 (regular reversing)
W2
Wash 2 (gentle reversing)
NO WCL
Wet clean function for Auxiliary 1 and 2
disabled (Auxiliary 1 and 2 are timed outputs.
W3
Wash 3 (no agitation)
W4
Wash 4 (medium reversing action)
BAL SW
Balance sensor
W5
Wash 5 (temp.-controlled cool-down)
BAL 1
Balance routine for 35 pound and 50 pound
capacity
W6
Wash 6 (extra low agitation)
BAL 2
Balance routine for 85 pound and 135 pound
capacity
W7
Wash 7 (no agitation, drain 1 open, no refill)
•
Left dot – poor balance condition
BAL 3
Balance routine for 250 pound capacity
•
Second dot from left – door lock switch
•
Third dot from left – Program Mode
RL
Fill from optional extra fill inlet to low level.
•
Fourth dot from left – high level reached
RM
Fill from extra fill inlet to medium fill.
•
Fifth dot from left – medium level reached
RH
Fill from extra fill inlet to high level.
•
Right dot – low level reached
DRTEMP
Temperature is above 160°F in drain to reuse
tank A or B step.