Alliance Laundry Systems UF35PV User Manual
Page 45
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Programming
43
F232059
Programming a Supply Step – Models
with 5 Supplies
The WE-6 microcomputer is capable of controlling up
to 5 separate supplies and up to 31 various
combinations of the 5 supplies. (Refer to Table 6 for a
listing of the energized supply compartments
represented by each display code.)
1. The computer must be in the Program Mode, and
the cycle programming sequence must be ready
for the next step.
2. Press the Supply key. The display will read “S”.
Now press the number key – 1, 2, 3, 4, or
5 – that corresponds to the desired supply valve.
If multiple simultaneous supply injections are
desired, follow this procedure:
●
After the Supply key has been pressed, press
any combination of keys 1-5 (up to five
individual digits per step) before pressing the
Enter key.
●
The computer will add those numbers to the
supply step. All desired supplies will be
turned on for the amount of time
programmed.
The display will show either a letter or number
code to indicate the supply combination selected.
For example, assume the computer is in the
Program Mode and the Supply key has been
pressed. Keys 1, 2, and 5 will be pressed one at a
time. After the last key is pressed, the display
will read “SN” as the first two digits of the
display, followed by the step number, which is
then followed by the cycle number being
programmed. Press the Enter key. The display
will read “M---S”. Now assign the desired time in
minutes and seconds for the supply injection to
last.
3. Press the Enter key and go to the next step in the
cycle.
Supply Display Codes (5 Supplies)
Code
Supply Number
0 = Supply Off
X = Supply On
5 4 3 2 1
1
0 0 0 0 X
2
0 0 0 X 0
A
0 0 0 X X
3
0 0 X 0 0
B
0 0 X 0 X
C
0 0 X X 0
D
0 0 X X X
4
0 X 0 0 0
E
0 X 0 0 X
F
0 X 0 X 0
H
0 X 0 X X
I
0 X X 0 0
J
0 X X 0 X
L
0 X X X 0
M
0 X X X X
5
X 0 0 0 0
6
X 0 0 0 X
7
X 0 0 X 0
N
X 0 0 X X
8
X 0 X 0 0
O
X 0 X 0 X
P
X 0 X X 0
Q
X 0 X X X
9
X X 0 0 0
R
X X 0 0 X
S
X X 0 X 0
T
X X 0 X X
U
X X X 0 0
V
X X X 0 X
W
X X X X 0
X
X X X X X
Table 6