beautypg.com

Magnum Venus Plastech ADVANTAGE User Manual

Page 8

background image

Advantage Gelcoater

2.

The Flush Pressure Gauge and Regulator monitor and control air

to the solvent flushing system.

3.

The Gun Pressure Gauge and Regulator monitors and controls the
air to the gun.

4.

(Optional) The Air Assist Gauge and Regulator monitors and
controls the air assist nozzle on the gun head.

Air Requirements

Clean, dry compressed air at a minimum of 90 PSI (6.3 kgs per sq. cm.)
with a minimum volume of 10 CFM (0.3 cm.) is required to operate the
unit, supplied through a ½ inch ID hose (1.25 cm.).

Tool Requirements

When using the Advantage Gelcoater, you should have all the following
tools, spare parts and supplies available before beginning operation or
repair:

One small hammer
One 6” adjustable wrench
One 12” adjustable wrench
One 7/16” open-end wrench
Two 14” pipe wrenches
Venus-Gusmer Wet-Mil Gauge
Eight lag bolts (1/2” x 3”; 1 cm x 8 cm) (Wall Mount Unit)
One pint of medium weight lithium grease
Flat-tip screwdriver with 1/4” tip width
Gelcoater Unit Tool Kit (shipped with unit)
Optional Porosity Kit (Part Number: 09983)

Material Requirements

You should have the following materials available before installing or
operating your Advantage Gelcoater:

Gelcoat resin (5 gallons or 19 liters)
Recommended solvent

4