beautypg.com

Magnum Venus Plastech ADVANTAGE User Manual

Page 42

background image

Advantage Gelcoater

When you have unscrewed the resin accumulator, disassemble it and
clean the parts with solvent. Allow the parts to air dry.

Figure 34: Unscrew Filter Tank

Disable Catalyst Pump

Remove the quick pin from the top of the catalyst pump and upper slave
arm.

Tilt the catalyst pump away from the resin pump until the catalyst pump is
resting against the vertical connecting post.

Trap the catalyst’s upper bearing block between the vertical connecting
post and the quick pin.

Shutdown Flush System

Turn the FLUSH regulator knob on the manifold until the gauge reads “0”.

Close air supply valve to the flush system.

Relieve the pressure in the solvent tank by gently pulling on the
pressure relief valve’s ring.

Cover Unit

Cover the Advantage Gelcoater with clean plastic sheeting to protect the

WARNING

Never unscrew the resin accumulator while it is still
charged. You may be seriously injured.

38