beautypg.com

Magnum Venus Plastech ADVANTAGE User Manual

Page 55

background image

Advantage Gelcoater

Annual Preventative Maintenance Checklist

Part:

Procedure:

Gauges and Regulators

Check for wear, damage, and proper

operation

Resin Accumulator

Remove and clean inside. Replace:

spring, ss ball, o-ring in charging
valve

Resin Filter

Wash and inspect filter screen for
damage

Power Head

Clean silencer with solvent and blow

dry. Replace o-rings, gaskets, springs
and balls.

Resin Pump Lower Assembly

Check the pickup hose and wand for

leaks or damage. Check inside the
center section for packing leaks

Flush Tank

Clean any residue and rinse with
solvent

Air Lines

Check for leaks, wear, and kinks.
Replace lines as needed.

Gun Head

Replace seals and o-rings

Catalyst Hoses

Replace seals and o-rings

Flush Lines

Replace Hoses

Resin Hoses

Replace Hoses

Pick-up Wand Hoses

Replace Hoses

Catalyst Pump

Check all bushings for wear and

damage. Check the pump cylinder for
wear. Replace ss balls, o-rings,
springs, piston seal and packings

51