Advantage Gelcoater

Begin Priming

Place the resin wand into the gelcoat resin container (see Figure 23).

Slowly turn the PUMP PRESSURE regulator (on the manifold) clockwise
until the pump begins moving. When the pump begins moving, stop
turning the regulator.

Let the pump run until resin is flowing out of the gun-head. The resin
should be flowing in a steady stream, with no air in the stream.

Turn the PUMP PRESSURE regulator on the manifold counterclockwise
until the regulator is completely off.

Figure 23: Place the Resin Wand into Resin Container

Charge Resin Accumulator

CAUTION

While being operated, the pump must have a sufficient
supply of resin. If the resin runs out, the pump will speed
up and cavitate, and damage can occur.

NOTE

When charging accumulators, the pump pressure
should be off and the gun locked open.