beautypg.com

Magnum Venus Plastech ADVANTAGE User Manual

Page 46

background image

Advantage Gelcoater

Disconnect the catalyst pump from the upper slave arm.

> Pull out the top quick pin in the upper slave arm.
> Pull up the piston rod priming knob and lean the top of the

catalyst pump toward the resin pump as far as it will go.

Empty any remaining catalyst from the catalyst jug.

Fill the catalyst jug with clean distilled water.

Slowly and gently pump the distilled water through the system by moving
the catalyst pump-priming knob up and down by hand.

Continue hand pumping until a stream of clean water flows from the gun
on both the upstroke and downstroke.

Empty the water from the catalyst jug and continue hand pumping until
water no longer exits the gun.

Blow, clean compressed air into the catalyst jug lines to remove
moisture.

Disable the catalyst pump by trapping the upper bearing block of
catalyst pump between the vertical post and the quick pin.

Figure 37: Disable Catalyst Pump

Flush Resin System

NOTE

Make sure the catalyst pump is still disabled and
pressures are off.

42