beautypg.com

Magnum Venus Plastech ADVANTAGE User Manual

Page 48

background image

Advantage Gelcoater

Figure 38: Remove Filter Tank

Clean the filter tank, spring, screen and filter core in solvent.

Reassemble accumulator and filter assembly.

Unlock the gun trigger.

Push flush button located on side of gun to flush gun block.

Shutdown Flush System

Turn the FLUSH regulator knob on the manifold until the gauge reads “0”.

Close air supply valve to the flush system.

Relieve the pressure in the solvent tank by gently pulling up on the pres-
sure relief valve lever.

Cover Unit

Cover the Advantage Gelcoater with clean plastic sheeting to protect the
system.

NOTE

If the filter is difficult to unscrew by hand, use a strap
wrench or a chain wrench to prevent damage to the
filter.

CAUTION

Always wear approved eye protection when working
near pressurized equipment.

44