Appendix C - Error Messages

The LCR-II was designed to perform diagnostic analysis of problems as they occur. If an error should occur, one of the
following messages may be displayed on the Lap Pad or printed on a Diagnostic Ticket (see troubleshooting section).
The list below explains the error message and any possible corrective action. The LCR-II was designed to handle most
foreseeable problems on its own. Consequently, if the suggestions listed are not successful, the assistance of a
trained authorized Liquid Controls service provider is recommended.

RUN TIME MESSAGE LIST

These messages may be displayed on the Lap Pad if an error occurs while the system is running.

FLASH CRC FAILURE

The CRC stored with an LCR-II data block indicates the data or CRC has been corrupted. A "REBUILD"
operation could possibly fix the problem. If not, try "CLEAR ALL". If that does not work, hardware may
be the problem and the unit should be returned to Liquid Controls for more analysis. NOTE: Before
performing a "CLEAR ALL" operation, print a calibration ticket.

FLASH WRITE FAILURE

A failure was detected while a data block was being written to the flash memory. See the resolution
suggestion under FLASH CTC FAILURE.

FLASH NOT INITIALIZED

This error indicates that a "CLEAR ALL" or "REBUILD" has been attempted without the Selector
Switch in CALIBRATION position.

RANGE ERROR

The data entered is not within the legal range limits for the field being changed.

DUPLICATE FLOW RATE ERROR

This message only appears when setting up multi-point calibration. When calibrating a multi-point
meter, the linearization points must all have unique flow rates. This message is displayed when a flow
rate being entered is already used on another point.

ADJACENT POINTS OUT OF 0.25% RANGE

This message only appears when setting up multi-point calibration. When calibrating a multi-point
meter, adjacent linearization points must be within a 0.25% correction of each other. To avoid this
error, select an additional flow rate and correction factor between the two points. More than one
additional point may be required. Adjacent flow rates entered for linearization cannot have their percent
error fields further than 0.25% apart.

COUNTER TEST IN PROGRESS…

A delivery has been started and the counter test is in progress. When the test is complete, flow will
start. This is not an error condition.

START ENABLED - SWITCH TO RUN TO BEGIN DELIVERY

The START button on the Lap Pad was pressed but the Selector Switch was not in the RUN position.
When the switch is put in the RUN position, the delivery will begin.