STEP 6: PRODUCT CALIBRATION CONTINUED
AUX MULT
This field is used to convert the quantity delivered, (e.g. GALLONS, LITRES) to an alternate volume or
mass unit such as CUBIC METERS, LBS, etc. The user must furnish an applicable conversion factor.
If AUX MULT is set to 0, it will not print on the delivery ticket. Example: To convert GALLONS to LBS,
AUX MULT is calculated as follows:
AUX MULT= (SpGr) x (8.345 Ibs/gal)
(Where SpGr is the specific gravity.)
AUX QTY
This field is used to display the volume delivered in terms of the alternate volume or mass unit.
AUX UNIT^
This field is used to define the auxiliary unit of measure that will be printed on the delivery ticket, i.e.,
GALLONS, LITRES, CUBIC M, LBS, KGS, BARRELS, or OTHER.
Press and the cursor will move to:
PT^
This field is used to calibrate the meter/register at up to 10 different flow rates for each product type/
calibration.
RATE
This field displays actual flow rate during delivery. Enter the actual flow rate for multi-point calibration.
UNITS^
Choose the units of measure to be displayed. The choices are GALLONS, LITRES, CUBIC M, LBS
(pounds), KGS (kilograms), BARRELS, or OTHER. Use the hi keys to scroll through the choices.
Press ENTER to make a selection.
RATE BASE^
Choose the time unit for measurement on the flow rate display. The choices are units PER HOUR,
PER MINUTE and PER SECOND. Use the
keys to scroll through the choices. Press ENTER to
make a selection.
%ERROR
This field contains the %ERROR difference against the base number.
Press and the cursor will move to:
PT^
1
Product Calibration - Screen 7
RATE
0.00
%ERROR
0.000
RATE BASE^
PER MINUTE
UNITS^
GALLONS
x 100
(Prover Qty - Meter Qty)
Prover Quantity
%Error =