Appendix A - Compensation Types & Parameters

The table below shows the supported methods of calculating the Volume Correction Factor (VCF). The method is
independently selectable for each product in Product Calibration. The table below shows the valid temperature
ranges for each table. The hold temperature, T

hold

, is the temperature that VCF is held at for temperatures < T

hold

and

> T

min

. This is done to allow compensation in very cold environments where further extrapolation of equations is not

allowed.

General

Linear

Linear

0 to 0.003

ºC

15

-90

N/A

+100

General

Linear

Linear

0 to 0.005

ºF

60

-130

N/A

+212

LPG

U SA

LPG

Europe &

C anada

Refined
Petroleum
Products

Europe &

C anada

Refined
Petroleum
Products

U SA

General

A PI Table 54C

Coefficient

0.000486 to
0.001674

ºC

15

-50

-40

+95

Lube Oil

Europe &

C anada

Ammonia

C anada

+40

-50

-40

+95

15

-30

-30

NH

3

N/A

N/A

60

Density
kg/m 3

A PI Table 54D

800 to 1164

ºC

15

ºC

+95

-50

-40

+200

A PI Table 6B

API Gravity

0 to 85

ºF

A PI Table 54B

653.0 to 1075.0

ºC

15

-50

-40

0.5 to 0.600

ºC

15

-46

-46

+60

T

m ax

A PI Table 24

Specific
Gravity

0.5 to 0.550

ºF

60

-50

-50

+140

Scale
ºC or ºF

Density
kg/m 3

Density
kg/L

T

base

T

m in

T

h old

Product

VCF Type

Parameter
Coefficient

Range

A PI Table 54