beautypg.com

Controlled Products Systems Group PAT1AC User Manual

Page 29

background image

27

TROUBLESHOOTING SECTION

OUTLINE

1 Single gate will not operate.
2 Dual gate will not operate.
3 Single or Dual gate opens or closes slowly.
4 Gate will not automatically close.
5 Gate begins to open or close, but stops and reverses after a couple of seconds.
6 Single Gate opens correctly then closes immediately or single Gate closes correctly and then opens

immediately.

7 Dual Gate opens correctly then closes immediately or dual Gate closes correctly then opens immediately.
8 Control board 15 amp fuse blows when “Open / Close Command” is given.
9 Remote/Transmitter will not operate the gate. (Multi-Code/Digi-Code and Low Current Receiver models)
10 Photo eye, safety loop or other safety accessory will not reverse the gate when closing.
11 Pressing the “RESET” button only, causes the gate to operate.
12 Gate opens with the transmitter but will not close with the transmitter
13 Gate only operates when the “LED INDICATOR” is pressed.
14 Oracle Remote/Transmitter will not operate the gate.

Terms and Definitions

LED -

Light Emitting Diode - small red lights on control board.

Control board- Located inside the metal box in the upper right corner.

Receiver -

Located inside the metal box in the upper left corner - coax cable connected to it.

Remote/
Transmitter -

Hand held push button, which is used to operate the gate - sends signal to receiver.

Actuator -

Connected to gate and hinge post - contains the motor, gearbox and extension tube.

Connector -

Control board has three types of connectors. Two white 8-pin connectors (X1 and X2) are
used to connect actuator to control board, one green 12-pin connector (J2) (located bottom
center of control board) to connect third party receivers and accessories to control board and
one white 4-pin connector (J5) to connect Oracle Enabled DFGCU to control board. All three
are plug type and can be disconnected (unplugged from control board) without disconnecting
wires.

Dip Switches - Small switches, which are located on the control board in two places. The primary set DS1, is

located in the upper left corner and the secondary set, DS2, is located in the lower right corner
of the control board with functions listed beside each. See manual (page 17-18) for more
information.

Push Buttons - Three are located on the control board. “Open / Close Command” used to operate the gate,

“LED Indicator” used to activate the LED’s and “Reset” used to reset the control board after
current sensing twice before a limit is reached.

Note: Never run the actuator while it is disconnected from the gate. Damage may

occur. Always have the actuator connected during troubleshooting in case the
operator starts working to prevent damaging internal components.

This manual is related to the following products: