Step 4c gate bracket installation, Important – Controlled Products Systems Group PAT1AC User Manual
Page 11
9
STEP 4c Gate Bracket Installation
(PUSH to Open Only)
The actuator is adjusted to the fully retracted or closed position from the factory. Once the actuator is
connected to the hinge mount tube, swing the gate to the desired closed position and block in place to secure
the gate. Move the actuator around so that the gate bracket can be attached to the gate. Ensure the gate is in
the fully closed position.
Clamp the gate bracket to the gate (verify actuator is level before welding). Be sure that your gate does not
move while clamping. The location of the gate will set your close position. The actuator cylinder will be
level if all steps were performed accurately. Weld gate bracket to the gate and verify actuator is still level.
Diagrams for help in determining hinge mount tube vertical position and gate bracket installed position.
Correct Installation
Incorrect Installation
Figure 9
Figure 9A
Figure 9B
Figure 9C
IMPORTANT:
The gate bracket must be welded in an area that can
withstand the full force of the gate. Do not simply weld
across a few pickets or bending of the pickets will occur.
Add a cross bar if necessary or weld the bracket to the
gate frame.
GATE SECURED IN DESIRED CLOSED POSITION
Figure 8
Weld while clamped
Figure 9D