beautypg.com

Controlled Products Systems Group PAT1AC User Manual

Page 22

background image

20

Total Remote/Transmitter Memory Deletion for Key Fob or Futura – 315 MHz

• On the DFGCU, press and hold the learn button down until the LED is on solid

• Release the learn button and press the learn button again

• Hold the learn button down for 8 seconds or until the red LED light goes steady

• Release the learn button

• The red LED light will double blink four times to signify exiting learn mode


Latch Mode for DFGCU

Turn the DFGCU dispswitch #6 on to enable latch mode for output 2.

To latch the gate open, the gate must be in either the fully open or fully closed position. If the gate is closed, press and
hold the remote/transmitter button used to operate the gate down until the gate is fully open. Once the gate stops
moving, release the remote/transmitter button.

If the gate is open, press and hold the remote/transmitter button used to operate the gate down. The gate should start to
close. Keep holding the button down and the gate will stop and reverse to the fully open position. Once the gate stops
moving, release the remote/transmitter button.

Release Gate from Latch Open Condition

Press and hold the remote/transmitter button used to operate the gate down for 8 seconds. Then wait for close timer to
close gate or press the remote/transmitter a second time to manually close the gate.

A command from any Oracle Pro 900 MHz devices installed on the system will release latch mode as well.. 900 MHz
devices include: Futura Pro remote/transmitters, push to exit buttons, GAPs, Mini Gaps or wireless keypads.

Programming Other Oracle Devices To DFGCU

Refer to the programming instructions supplied with your Oracle product for programming instructions.

This manual is related to the following products: