Circuit Board Terminal Description For Accessories

Patriot Control Board




















TERMINAL DESCRIPTION

1

+ 12 vdc Output.

*Maximum current output 1.5 amp (1500 milliamps)

2 Common

Ground

Input

3 Push

Button

Input. (normally open contacts)

Push button, radio control, keypad, etc.

4

Open Safety Edge (normally open contacts)

(Stops gate when opening)

5

Close Input (normally open contacts)

6

Secondary Entrapment Input (normally open contacts)

7

Common Ground Input

8

Stop Circuit Input (normally closed contacts)

* DS1 switch #8 must be on for stop circuit function to be enabled.

9

Free Exit/Open Input (normally open contacts)

Loop input or any hold open input such as a 7-day timer, telephone access unit, or

maintain contact switch (normally open contacts). These devices open the gate and

will prevent the gate from closing if the contact is maintained. Once the contacts have

been released, the gate can be closed with a closing signal device or the automatic

close timer feature. Receiver relay 2 pre-wired for latching open.

10

Center Loop or Under Gate Loop Input (normally open contacts)

11 Safety

Loop/Photo-eye/Reversing Edge Input (normally open contacts)

12

Motion Detector Input (normally open contacts)

(Stops a closed gate from opening)(Active on close limit only)

* DS2 Switch 4 must be on for Motion Detector function to be enabled

The Accessory connector is a plug, which can be
removed from the control board for ease of wiring
and troubleshooting purposes.
Place finger below connector and pull out to
remove.

Siren Output

OPEN/CLOSE
COMMAND

Vehicular Gate Operator

Gate Weight Max. Load: 650 lbs.

LED INDICATOR

S2

RESET

Entrapment

S
E
C
U
R
I
T
Y

S
H
U
N
T

C
O
M
M
O
N

G
N
D

M
A
G
L
O
C
K

S
O
L
O
N
O
I
D
L
O
C
K

C
O
M
M
O
N

G
N
D

O
U
T
P
U
T
+
1
2
V

O
N

2
3
4

1

SOLONOID LOCK ENABLE
MAGNETIC LOCK ENABLE
SECURITY SHUNT ENABLE
MOTION DETECTOR ENABLE

15

5

0

10

TIMER TO CLOSE

ADJUSTMENT

Timer

ADJUSTMENT

Class I or Class II per UL325

J2

INDICATORS

1-

+12V OUT 1.5 AMP MAX


2- COMMON

GROUND


3-

PUSH BUTTON INPUT


4-

OPEN SAFETY EDGE


5- CLOSE

INPUT


6-

SECONDARY ENTRAPMENT DEVICE INPUT


7- COMMON

GROUND


8-

STOP CIRCUIT INPUT N/C


9-

FREE EXIT / OPEN INPUT


10-

UNDER GATE / CENTER LOOP INPUT


11-

SAFETY LOOP / REVERSING EDGE INPUT


12-

MOTION DETECTOR INPUT

1 2 3 4 5 6 7 8 9 10 11 12

J2

BOTH ON FOR DUAL

DS1 SWITCH SETTINGS

FACTORY SETTINGS

SW-1

AUTO CLOSE TIMER ENABLE

OFF

SW-2

TIMER TO CLOSE WILL ACTIVATE ON LIMIT ONLY

ON

SW-3

MASTER GATE ENABLE

ON

SW-4

SLAVE GATE ENABLE

OFF

SW-5

SOLENOID LOCK OPTION, SEE INSTALLATION MANUAL

OFF

SW-6

SOFT STOP RETRACT ENABLE

OFF

SW-7

SOFT STOP EXTEND ENABLE

OFF

SW-8

STOP CIRCUIT ENABLE

OFF

SW-9

OPERATING DIRECTION REVERSE

OFF

SW-10

SOFT START ENABLE FOR SW6 AND SW7

OFF

1
2
3
4
5
6
7
8
9
10

O
N

DS1

PATRIOT CONTROL BOARD

USAutomatic

MADE IN USA

CURRENT SENSE
ADJUSTMENT

0

10

5

MASTER

Sensitivity

CURRENT SENSE
ADJUSTMENT

0

10

5

SLAVE

Sensitivity

15

J5

1 2 3 4