beautypg.com

Limit switch adjustment, Pull to open installation only, Push to open installation only – Controlled Products Systems Group PAT1AC User Manual

Page 17: Extend limit shaft retract limit shaft limit nut, Limit adjustment slots

background image

15

Limit Switch Adjustment

The limit switch adjustments are located on the bottom of the actuator. Remove the dust plug to make
adjustments. A flat blade screwdriver is included with the operator for adjustment purposes.

If soft stop is going to be used turn dipswitch 6 or 7 (see page 17) on at this time. Prior to operating the gate the
actuator extension tube needs to be turned 6 turns in the counter clockwise direction. Disconnect from gate bracket
to turn.

NOTE:

ALL ADJUSTMENTS SHOULD BE MADE IN THE MID TRAVEL (1/2 OPEN) POSITION. DO NOT
FORCE THE ADJUSTMENT; FORCING WILL DAMAGE THE LIMIT ASSEMBLY. REMOVE THE
ADJUSTMENT TOOL AFTER EACH ADJUSTMENT.

NOTE: For adjustment purposes only you might find it easier to flip the actuator upside down to access
the limit switch adjustment screws. Once adjustments are completed, flip the actuator back to the
correct final installation position. See page 8, figure 6.

The following will assist you. Shown below are adjustments for pull to open and push to open installation.

Pull to Open Installation Only

To extend more or close gate more.

Turn the extend adjust clockwise.

To extend less or close gate less.

Turn the extend adjust counter clockwise.

To retract more or open gate more.

Turn the retract adjust clockwise.

To retract less or open gate less.

Turn the retract adjust counter clockwise.

Push to Open Installation Only

To extend more or open gate more.

Turn the extend adjust clockwise.

To extend less or open gate less.

Turn the extend adjust counter clockwise.

To retract more or close gate more.

Turn the retract adjust clockwise.

To retract less or close gate less.

Turn the retract adjust counter clockwise.

Bottom view of Actuator

RETRACT



EXTEND

Extend limit shaft
Retract limit shaft





Limit Nut

Limit Adjustment slots

Top of Actuator





White close limit wire

Orange open limit wire

Green common

This manual is related to the following products: