Function of program switch settings – ds2, Emergency manual release, Ds2 programming dipswitches – Controlled Products Systems Group PAT1AC User Manual
Page 20: Factory settings are shown in bold italic type, Manual release pin
18
FUNCTION OF PROGRAM SWITCH SETTINGS – DS2
DS2 Programming Dipswitches
Factory settings are shown in bold italic type
1 Solenoid lock enable / Gate in operation indicator
ON
Solenoid lock output energizes half second before gate begins to move and releases 3
seconds after gate begins to move. For gate in operation indicator to operate DS1 SW 5
must also be ON.
(Energizes = +12 vdc output 1.5 amp max)
OFF
Solenoid lock / gate in operation indicator is inactive
2 Magnetic lock enable
ON
Magnetic lock output energizes on Master Limit and releases half second before gate
begins to open
(Energizes = +12 vdc output 1.5 amp max)
OFF
Magnetic lock output is inactive
3 Security Shunt Circuit Enable / Open Gate Indicator / Photo-Eye Power Control
ON
Security shunt circuit relay is active (closed circuit)(wire in parallel)
Relay activates half second before gate begins to open and stays activated until 4
seconds after gate reaches a closed limit.
OFF
Security shunt circuit relay is inactive (open circuit)
4 Motion Detector Enable
ON
Enables motion detector input J2 pin 12 (if input is activated, gate will not open)
OFF
Disables motion detector input J2 pin 12
Emergency Manual Release
NOTE: Before detaching actuator arm from gate, turn DS1 dipswitch 3 and 4 to the “OFF” position
(page 17). This will keep the actuator from operating while disconnected from the gate.
Remove the manual release pin at the gate bracket and open the gate by hand. Secure the gate before
attempting to pass through.
Manual Release Pin
Secure in place with pull clip or
with #2 lock. Release pin is
predrilled for this purpose.
Siren Output
OPEN/CLOSE
COMMAND
Vehicular Gate Operator
Gate Weight Max. Load: 650 lbs.
LED INDICATOR
S2
RESET
Entrapment
S
E
C
U
R
I
T
Y
S
H
U
N
T
C
O
M
M
O
N
G
N
D
M
A
G
L
O
C
K
S
O
L
O
N
O
I
D
L
O
C
K
C
O
M
M
O
N
G
N
D
O
U
T
P
U
T
+
1
2
V
O
N
2
3
4
1
SOLONOID LOCK ENABLE
MAGNETIC LOCK ENABLE
SECURITY SHUNT ENABLE
MOTION DETECTOR ENABLE
15
5
0
10
TIMER TO CLOSE
ADJUSTMENT
Timer
ADJUSTMENT
Class I or Class II per UL325
J2
INDICATORS
1-
+12V OUT 1.5 AMP MAX
2- COMMON
GROUND
3-
PUSH BUTTON INPUT
4-
OPEN SAFETY EDGE
5- CLOSE
INPUT
6-
SECONDARY ENTRAPMENT DEVICE INPUT
7- COMMON
GROUND
8-
STOP CIRCUIT INPUT N/C
9-
FREE EXIT / OPEN INPUT
10-
UNDER GATE / CENTER LOOP INPUT
11-
SAFETY LOOP / REVERSING EDGE INPUT
12-
MOTION DETECTOR INPUT
1 2 3 4 5 6 7 8 9 10 11 12
J2
BOTH ON FOR DUAL
DS1 SWITCH SETTINGS
FACTORY SETTINGS
SW-1
AUTO CLOSE TIMER ENABLE
OFF
SW-2
TIMER TO CLOSE WILL ACTIVATE ON LIMIT ONLY
ON
SW-3
MASTER GATE ENABLE
ON
SW-4
SLAVE GATE ENABLE
OFF
SW-5
SOLENOID LOCK OPTION, SEE INSTALLATION MANUAL
OFF
SW-6
SOFT STOP RETRACT ENABLE
OFF
SW-7
SOFT STOP EXTEND ENABLE
OFF
SW-8
STOP CIRCUIT ENABLE
OFF
SW-9
OPERATING DIRECTION REVERSE
OFF
SW-10
SOFT START ENABLE FOR SW6 AND SW7
OFF
1
2
3
4
5
6
7
8
9
10
O
N
DS1
PATRIOT CONTROL BOARD
USAutomatic
MADE IN USA
CURRENT SENSE
ADJUSTMENT
0
10
5
MASTER
Sensitivity
CURRENT SENSE
ADJUSTMENT
0
10
5
SLAVE
Sensitivity
15
J5
1 2 3 4