3.3 Troubleshooting Continued
Symptom
Possible Solution
(
s
)
Gate closes and
opens continuously.
Gate starts to close,
then reverses to
open.
Alarm sounds for 5
minutes and then
beeps once every 5
seconds. Operator
will not run.
•
Disconnect the gate from the operator and check that the gate operates freely without any binding.
•
Check the loop detector LED’s and input LED’s. Any that flash ON will cause the gate to reverse.
•
If a shadow loop is used, check for proper wiring. A mis-wired shadow loop detector will cause the
gate to reverse.
•
Continue troubleshooting or replace the circuit board.
•
Operator is in a “hard shutdown” condition. Reset switch must be activated to return operator to
normal operation, see Hard Shutdown Section 2.5, page 24.
•
Check for any input or loop detector LED’s that are ON.
•
Check that the operator is running in the proper direction (see “gate closes but will not open”).
•
Check the SELF TEST jumper, see page 16.
3.4 Accessory Items
The following accessory items are available for the 115 VAC Control Boxes.
Photo Cell - Non-contact (photo-cells) sensors for use as a secondary entrapment protection device.
MMTC, Inc. Model IR55
P/N 8080-010
MMTC, Inc. Model 60-278
P/N 8080-011
Carlo Gavazzi Type PMP12
P/N 8080-030
Carlo Gavazzi Type PMT
P/N 8080-031
Loop Detector - Detectors plug directly into ports on circuit board simplifying wiring.
P/N 9410-010 - Single channel detector P/N 9409-010 – Two-channel detector
Magnetic Lock - Magnetic Gate Lock Kit provides an excellent means to secure swing gates and is a fail-safe device allowing
emergency vehicle access upon power outage. P/N 1216-080 and P/N 1216-081
Remote Reset - Provides a remote station to reset an operator in a hard shutdown condition. Must be mounted in line-of-site of
the gate and operator. Includes visual and audible signals. P/N 1404-080.
Interconnect Cable - Interconnect wire cable contains all the necessary wires to interconnect primary / secondary operators.
Cable length 30 feet. P/N 2600-755 Cable length 40 feet. P/N 2600-756 Cable length 50 feet. P/N 2600-757
Time Clock - 7 day and 365 day time clocks can be used to automatically open gate at pre-set time and days. Compact clock fits
inside the operator. P/N 2600-791 - 7 day clock P/N 2600-795 - 365 day clock
Torsion Rods - Torsion rod assembly is used on uphill swing gates for counter balance. P/N 1203-084
Hinges - Heavy-duty ball bearing hinges provide easy swing gate operation. P/N 1200-009, P/N 1200-019, P/N 1200-039.
Surge Devices - High and low voltage surge suppressors help prevent circuit board failure caused by lightning strikes and
power surges. P/N 1876-010 - High Voltage P/N 1878-010 - Low Voltage
Gate Scale - Use to test torque required to move gate. P/N 2600-225
Speed Bumps - Prefabricated six-foot speed bump reduces traffic speed through gate system. P/N 1610-150
Battery - 12 Volt 3 Amp Hour. P/N 1801-009. Two (2) required.