beautypg.com

5 main terminal wiring – Controlled Products Systems Group 4302-111 User Manual

Page 15

background image

4302-065-F-1-13

13

1.5 Main Terminal Wiring

Key Switch

(Dry contact)

Keypad

(Dry contact)

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20

Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating
the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use. When installing
electrical equipment make certain all wiring complies with local code requirements. Do not power any control devices from the
circuit board other than low voltage devices.

1. Com

Relay Com

Relay N.O.

24 V

olt Power Com

24 V

olt Power

#13 Com

#6 - N.O.

#12 N.C.

3. 24 V

olt

2. Relay

3-Wire RF Receiver

4-Wire

RF Receiver

Mount inside of

control box door.

Safety Opening Device

(Dry contact)

SW 1,
Switch 3 ON

Telephone
Entry

Note: Telephone entry device must
use a separate power source.

SW 1

1

ON

2

3

4

5

6

7

8

Connect optional control devices
to the main terminal. Use 18 AWG
wire for all low voltage wiring,
maximum distance 3000 feet. Use
a low voltage surge suppressor,
(DoorKing P/N 1878-010) if low
voltage wire runs exceed 1000
feet. All control device inputs to
the terminal must be NORMALLY
OPEN.

For individual terminal descriptions, see previous page.

#7 - Com

#4 - N.O.

#5 - Com

#4 - N.O.

#5 - Com

#4 - N.O.

#5 - Com

Reversing input on Terminal #8
functions ONLY while the gate is at
the FULL OPEN position or during
the CLOSING cycle. It MUST NOT be
used as an input for a secondary
entrapment protection device during
the OPENING gate cycle. Refer to
Section 1.3, page 11 Secondary
Entrapment Protection Wiring.

Coax Antenna Kit

P/N 1514-073

Antenna

mounted

outside

control box.

P/N

8055-0

81

15 ft Coax

Switch 3 ON

Magnetic Lock

Note: Circuit board provides
24 VDC to power maglock.

Contact rating is 1 amp
maximum at 24 Volts.

SW 2

1

ON

2

3

4

Three 115 VAC Convenience Outlets.
Power safety and opening devices
that require 115 VAC power.

Deluxe Control Box ONLY

This manual is related to the following products: