beautypg.com

4 main terminal description – Controlled Products Systems Group 4302-111 User Manual

Page 14

background image

4302-065-F-1-13

12

1

2

3

4

5

6

7 8

9 10 11 12 13 14 15 16 17 18 19 20

1.4 Main Terminal Description

Operation of the relay is dependent on the setting
of SW 2, switches 1 and 2. Relay contact can be
set for Normally Open (NO) or Normally Closed
(NC) operation.

Contact rating is 1 amp

maximum at 24 Volts.

SW 2, Switch 1 OFF, Switch 2 OFF:

Relay activates when gate is OPEN.

SW 2, Switch 1 OFF, Switch 2 ON:

Relay activates when gate is OPEN, OPENING or CLOSING.

SW 2, Switch 1 ON, Switch 2 OFF:

Relay activates when gate is OPEN or OPENING.

SW 2, Switch 1 ON, Switch 2 ON:

Relay activates when gate is OPENING or CLOSING.

NO

NC

Maglock: SW 2,
Switch 3 ON, 1 sec.
delay at start.

SW 1

When gate is closed, input will open gate.

When gate is open and auto close

timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.

When gate is open and auto close

timer SW 1, switch 4 is turned OFF,
input will close gate.

When gate is closing, input will

reverse gate.

SW 1, switch 3 is ON, terminal #4

functions as a normal FULL open input
(Normal Setting).

SW 1, switch 3 is OFF, terminal #4

becomes the output from a plug-in loop
detector installed in the EXIT loop port
of the circuit board.

When gate is closed, this input has no

affect on the gate operator.

When gate is open and auto close

timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.

When gate is open and auto close

timer SW 1, switch 4 is turned OFF,
input will prevent gate from closing.

When gate is closing, input will

reverse gate when SW 1, switch 5
is OFF.

SW 1, switch 5 ON is NOT used.

4

8

2

15

12

10
11

DC power is not present on the
board until first initial cycle of gate.

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

SW 2

1

ON

2

3

4

SW 2

1

ON

2

3

4

Low V

o

ltage Common

Low V

o

ltage Common

For specific wiring information, see next page.

Low V

o

ltage Common

Low V

o

ltage Common

Dr
y Relay Contact

Alarm Reset

Dr
y Relay Contact

24 VDC - 250 ma max.

Full Open

Full Open

Full Open

Standard Reverse

Not Used

Not Used

DC Lock Power Common

24 VDC Maglock Power

12 V

o

lt Batter

y

Low V

o

ltage Common

24 V

AC Input

24 V

AC Input

This manual is related to the following products: