beautypg.com

3 secondary entrapment protection wiring, Ul 325 terminal – Controlled Products Systems Group 4302-111 User Manual

Page 13

background image

4302-065-F-1-13

11

1 2 3 4 5 6 7

8

9

10 11 12 13 14 15 16 17 18 19 20

1.3 Secondary Entrapment Protection Wiring

Closing-Direction

Protection

Closed Gates

Open Gate

Open Gate

Entrapment Protection

Opening -Direction

Entrapment Protection

Opening -Direction

Photo Sensors

PHOTO OPEN (Photo Sensors)
Stops gate movement in the open cycle. Gate resumes
normal operation when the input (obstruction) is cleared.

Not used

Not used

Not used


COMMON
Terminal for the secondary entrapment device input.

COMMON
Not used.

1

1

2
3
4

5

5

6

SW 1

Switch 5 Must be OFF

In addition to the inherent entrapment sensing system, this operator has provisions for the connection of a non-contact (type
B1) secondary entrapment protection device. This is required by UL 325 standards.

Entrapment protection devices are required to reduce the risk of injury. Install sensors where the risk of entrapment or
obstruction exists while gate is moving.

UL 325 Terminal

Main Terminal

UL 325 Terminal

1

ON

2

3

4

5

6

7

8

4302

Closing-Direction Protection

UL 325 Terminal Note: The 6-pin
terminal can be unplugged from circuit
board for easy wire connections.

When closing-direction gate’s

photo beam get obstructed,

gates will reverse back to the

full open position.

Standard Reverse

Low V

oltage Common

Standard Reverse input on Terminal
#8 functions ONLY while the gate is
at the FULL OPEN position or during
the CLOSING cycle. It MUST NOT be
used as an input for a secondary
entrapment protection device during
the OPENING gate cycle.

This manual is related to the following products: