CellCom/FreeSpeak Firmware Update Procedures
Rev: 6.05
VGC Part No.- 810372Z-MAN-6
Page 22 of 49
CELLCOM / FREESPEAK
BASESTATION FIRMWARE
UPGRADE GUIDE
START
Does
the system Boot into
its normal operational
state?
1. Make back ups of the maps on the PC System.
2. If possible, retrieve the map from the basestation
and back it up
3. Install the new CellCom toolkit
1. Open v2 Config Editor
2.
Click on‟ Send File‟
3. Enter IP address of the basestation and change the
Basestaion IP address to match
4.
Select the map called ”CC10_SYS1_upgradeFix.map”
You will find this map on the CD in directory
“\Firmware\Base station\APP” and click „Open‟
Press and Hold In the “Enter” button
and power up the basestation holding
the ”Enter” button in for 12 seconds.
Did the
menu option “EXIT?...Yes”
appear on the front panel
display?
On Attempt 1:
Rotate the “setup” knob until the menu
option “WRITE DEFAULT MAP?...YES” appears and
press “Enter”. Wait for the Basestation to reset
On Attempt 2:
Rotate the “setup” knob until the menu
option “ERASE ALL FIRMWARE?...YES” appears and
press “Enter”. Press hold CH A TALK to proceed erasing.
Wait for the Basestation to reset. Re-enter the menu
options and repeat the erase firmware for the second
bank..
Rotate the “setup” knob until the menu option
“ERASE ALL FIRMWARE?...YES” appears and press
“Enter”. Press hold CH A TALK to proceed erasing. Wait
for the Basestation to reset.
No
Yes
Yes
No
Does
the system Boot into
its normal operational
state?
Yes
FINISHED
Using the “v2 Config Editor” send the new basestation
file called “710805Z.4kr”
You will find this file on the CD in directory
“\Firmware\Base station\APP”
After the Basestation has reset. Check the Software
version from the front panel SYSTEM->INFO menu. .
*Is the
firmware version
correct?
Upgrade the second bank by again using the “v2
Config Editor” send the new basestation file called
“710805Z.4kr”
You will find this file on the CD in directory
“\Firmware\Base station\APP”
After the Basestation has reset. Check the Software
version from the front panel SYSTEM->INFO menu. .
Yes
No
*Is the
firmware version
correct?
No
Is this the
third attempt to access this menu
set without success?
Yes
No
GO TO START 2 ON
NEXT PAGE
Using the “v2 Config Editor” send the new Xilinx FPGA
image file called “CCV2FPGA2_1.xsvf”
You will find this file on the CD in directory
“\Firmware\Base station\FPGA\V2_1”
Yes
Does
the unit sit on “Booting
Please Wait....100% for
over 1 minute?
Enter the v2.0 Passcode
*Is the
firmware version
correct?
No
Press and hold the Call/Reply key to revert to the previous Xilinx version.
There is an unknown hardware problem. Please contact tour Vendor
Please follow the procedure again to apply v 1.5.7
Yes
FINISHED
No
Is the
unit s/n 1761 or
above?
Yes
Open the unit and replace the Boot
PROM and memory SIMM with the
upgrade parts. Close the unit
No
Does
message “please serially
download a configuration map”
appear ?
NO
Download your current map via
the serial cable
Power cycle the unit
YES