E-que front-panel card lights and buttons, Reset button, Power supply & status lights – Clear-Com Eclipse-Omega User Manual
Page 62: Volt power supply light, E-que front-panel card lights and buttons -2, Reset button -2, Power supply & status lights -2, Volt power supply light -2
Clear-Com
Eclipse Omega Instruction Manual
4 - 2
E-QUE FRONT-PANEL CARD LIGHTS AND BUTTONS
Reset Button
Pressing the reset button causes the card and all links to momentarily
stop their current activity and to restart.
During the reset, configuration information downloads to the card from
the CPU card. If the entire system is operating except for one E-QUE
card press the reset button for that card only.
Note: The reset button is slightly recessed from the front panel to
prevent it from being accidentally pressed. A tool such as a
bent paper clip is required to press this button.
Power Supply & Status Lights
+3.3-Volt Power Supply Light
The matrix’s +3.3-volt power supply provides electric current to this
green light. When lit, the light indicates that the +3.3-volt supply is
present and supplying power to the card.
1