Conditions that cause an alarm, Conditions that cause an alarm -16, Figure 2-4 power supply module’s front door -16 – Clear-Com Eclipse-Omega User Manual
Page 36
Clear-Com
Eclipse Omega Instruction Manual
2 - 1 6
The XP type power supplies (part 740101Z) may need to be adjusted if
E-QUE, E-FIB, IVC-32 or LMC-64 interfaces are installed. For details
of the adjustments please refer to the system upgrade manual (part
810377Z).
Power-One power supply units (part 720379Z) should not be adjusted.
Figure 2-4: Power supply module’s front door
CONDITIONS THAT CAUSE AN ALARM
The following conditions trigger an alarm:
• If any of the voltages produced by the first power supply unit fall
below normal levels.
• If any of the voltages produced by the second power supply unit fall
below normal levels.
• If an internal matrix alarm condition activates a matrix relay to turn on
an external alarm.
• If the active CPU card exceeds a temperature threshold.
• If either of the CPU cards is removed from the matrix.
Power Supply LIghts
+12 Volt Light
+ 5 Volt Light
+3.3 Volt Light
--12 Volt Light
Alarm Lights
Main Alarm Light
External Alarm (EXT ALARM) Light
Temp Alarm Light
Fan-Fail Alarm Light
PSU1 Fail Light
PSU2 Fail Light
Fan-On Alarm Light
Alarm Reset Button
Euro Cassette
Power Supply 1
Euro Cassette
Power Supply 2
Euro Cassette
Alarm Lights