beautypg.com

Opto-isolated mode, Opto-isolated mode -19 – Clear-Com Eclipse-Omega User Manual

Page 105

background image

Clear-Com
Eclipse Omega Instruction Manual

7 - 1 9

general-purpose input. The current is supplied by a voltage output on
the GP IN connector.

To select a mode, move the J1 jumper on the CPU rear card to one of
two positions. The J1 jumper is located on the inner-matrix side of the
DB-25 connector.

• For opto-isolated mode, fit the J1 jumper across pins 1 and 2.

• For non-isolated mode, fit the J1 jumper across pins 2 and 3.

Note: It is recommended that the connector is set to the fully

opto-isolated mode.

Opto-Isolated Mode

Figure 7-12 shows the opto-isolated connection.

Figure 7-12: Opto-Isolated Connection to GPI Connector

In this mode, a DC voltage of between 7 and 24 volts is required at the
EXTVIN+ pin with relation to the EXTVIN– pin. To cause an input to
detect an active signal, current must flow from the relevant input pin.

The external device should draw no current to cause an inactive input
and at least 5 mA to cause an active input. The opto-isolator drive line
contains a 1.5 kOhm resistor to limit the current through the
opto-isolator. Therefore the input pins can be connected directly to the
EXTVIN– level to cause an active input.

The voltage level at the external input pin should not be allowed to go
below EXTVIN– or above +6 V with respect to EXTVIN–.

+

C
10uF_10V

D
BYG22D

+

C
10uF_25V

INPUT 1

EXTVIN-

EXTERNAL INPUT 2

EXTVIN+

INPUT 2

R29 1.5K

U

LM78L05ACM

VIN

8

VOUT

1

7-24V

R30

1.5K

U

MOCD207-M

1

3

2

4

8

7

6

5

EXTERNAL INPUT 1

R
33K2

+3V3

R
33K2

+3V3