Clear-Com HX System Frames User Manual
Page 74
D
Sample rate or Sf (Sampling frequency)
A
green
LED indicates the current sampling rate of the MADI channels. The
sample rate is determined in EHX when a video sync is used, or automatically
detected from the clock source when a Word clock is used.
Note:
If the quantity of channels is 32, the sampling rate is either 44.1KHz, 48KHz or
96KHz.If the quantity of channels is either 56 or 64, the sample rate is either
44.1KHz or 48KHz.
The Sample rate LED on the front of the E-MADI64 will oscillate between two
sample rates when the received sample rate differs from the transmitted
sample rate.
E
Channels
A
green
LED indicates the quantity of MADI channels. The number of
channels is determined in EHX. You can select from 32, 56 or 64 full duplex
channels of digital audio.
Note:
Channel LEDs on the front of the E-MADI card will oscillate between two
channel numbers when the number of channels received differs from the
number of channels set in EHX.
F
Diagnostics
Active LED
The Active (matrix data) LED
flashes green
(1:1 at 0.5Hz) to indicate
successful communication between the E-MADI64 master card and the CPU
card.
Error LED
The Error (status) LED is lit
solid red
when there is no clock source or MADI
input.
Note:
During boot up, the Active and Error LEDS flash rapidly until the boot
sequence is completed.
Table 16: Key to E-MADI64 lights and controls
74
Eclipse HX-Delta User Guide