8.4 E1 Trunk and Direct Modes

The E-QUE interface can be used for both direct E1 to E1 port connections or to provide
trunk linking via a network between systems. The E1 connections can be made between
Eclipse systems or between Eclipse systems and compatible third-party equipment. E1
mode provides 30 channels of G.722 or G.711 encoded audio available on each of ports 1
and 5, giving 60 channels per card.

The E1 specifications are:

• HDB3 Encoding.

• Long Haul Receive Signal Level.

• E1 120 Ohm Transmit Pulse Amplitude.

• Balanced.

• 120 Ohm Line Impedance.

• No Signaling.

• G.722 or G.711 64 kbit/s Audio Encoding.

• Tx Clock locally generated.

• Rx Clock Line Recovered.

Figure 36: Matrix to Matrix direct E1 Trunking

shows E1 trunking using a direct connection

between the matrices using a CAT5 crossover cable. The E-QUE interface should be set to
E1 Direct in EHX hardware setup.

102

Eclipse HX-Delta User Guide