With the system in Disarm Mode.
Press , ,
Admin Password
The system is now in the Programming Mode
Use the and buttons to scroll through the programming menu.
Press to select the displayed programming function or sub-menu.
Note:
After programming all required functions press to leave Programming mode
and return to Disarm mode.
RESET FACTORY DEFAULT
1. Press
, to place the system in Test Mode.
User Password
2. Undo the Control Panel cover fixing screws and open the cover.
3. Switch OFF the mains supply to the plug-in PSU Adaptor and remove the plug
from the DC power socket in the Control Panel.
4. Remove either back-up battery and disconnect the battery leads.
5. Set jumper link P1 to the ON position.
6. Reconnect the battery leads and replace the back-up battery in position.
Reconnect the PSU Adaptor plug to the DC power socket in the Control Panel
and switch On the supply to the PSU Adaptor.
7. As the Control Panel powers-up, ‘EEPROM RESET’ will be displayed while the
factory default conditions are restored to memory. Once the memory reset
has been completed ‘DISARM READY’ will be displayed. The Control Panel
will now be reconfigured with all factory default settings.
8. Reset jumper link P1 into the OFF position.
9. Close the Control Panel cover and refit the fixing screws.
PROGRAMMING INSTRUCTIONS
Note: After recording the message, press to stop the recorder and cancel
any remaining message time.
REPLAY ALARM MESSAGES
Scroll through the menu until ‘:3 Play Voice’ is displayed and press .
Scroll through the available menu options until the required message type is
displayed.
a) Main + Intruder Messages
b) Main + Fire Messages
c) Main + Panic Messages
d) Main + Medical Help Messages
To replay the message press .
Press to return to the top level Voice Dialer setup menu.
CALL ROUTING
This feature controls which telephone numbers are enabled in the dialing
sequence and are dialed when the voice dialer is activated.
The current routing sequence is displayed on screen in the order of phone
numbers 1-6. An ‘X’ indicates the number is disabled and a ‘O’ indicates the
number is enabled in the routing sequence. e.g. A display = “00000x” indicates
a call sequence of phone nos.1,2, 3, 4 and 5, phone number 6 is disabled and
not called.
Default setting: all numbers disabled.
Scroll through the menu until ‘:4 Alarm Dial’ is displayed. The current settings
will also be displayed.
Scroll through the available menu options until the required telephone number
(1-6) to be configured is displayed. The current status will also be displayed.
To change the setting press .
Press to enable the number in the routing sequence, or
Press to disable the number in the routing sequence.
TEL CONFIRM TIMES
This sets the number of acknowledged phone numbers required to stop the
voice dialer. For example if set to “2” then the dialing sequence will continue
until an acknowledgment is received from two different numbers, (e.g. Phone
No. 1 and Phone No. 3). The recipient must acknowledge the message by
pressing the button on their telephone keypad.
EN