Electrical data – Burkert Type 8712 User Manual
Page 22

22
Technicaldata
Type 8006, 8702
6.7.
electrical data
Power supply
24 V DC ± 10%; residual ripple < 2% (5% for UL devices)
Power supply (not provided) for UL devices
Power supply limited to class 2
Power required (max. in Watt) depending on the type of the
device
8006
8702
8626
8712
12.5
5
36.5
14
MFC only:
Analogue input (configurable)
• 0/4 - 20 mA
Max. input impedance: 300
Ω, resolution: 5 µA
• 0 - 5/10 V
Min. input impedance: 20 k
Ω, resolution: 2.5 mV
Binary inputs (configurable)
3 binary inputs
Low active
Connect to DGND for activation
Analogue output (configurable)
• 0/4 - 20 mA
Max. load: 600
Ω, resolution: 20 µA
• 0 - 5/10 V
Max. current: 10 mA, resolution: 10 mV
On certain versions: Field bus communication
(alternative to "analogue input + outputs")
PROFIBUS DP V1, DeviceNet or CANopen
Relay outputs (configurable)
2 relay outputs
Potential-free changer 60 V, 1 A, 60 VA
LEDs (configurable)
4 LEDs
Status display for Power, Communication, Limit, Error
Electrical connections
M16 female fixed connector, 8-pin and Sub-HD, 15-pin
Additional connections for version with field bus
M12 male or female fixed connector, 5-pin, or Sub-D female fixed connector,
9-pin