beautypg.com

Appendix simple trouble shooting table – eLine Technology ANPTZ-56-37R User Manual

Page 39

background image

eLineTechnology.com

37

For this case,we suggest you add one RS485 distributor.It can solved all problem.Avoid production

problems and improve communications reliability.

Appendix Simple Trouble Shooting Table

Problems Possible

causes

solutions

No action, no picture

when power is switched

Power supply adaptor

damaged or Power supply

not sufficient

Replace

Wrong contact of power

cables

Correct

Engineering line fault

Exclude

Abnormal self-check,

image shown with motor

Mechanical failure

Repair

Camera inclined

Reinstall

Power supply not sufficient

Replace, better to place the

adaptor nearby the unit

Normal self-check

but no image

Wrong contact of video

lines

Correct

Bad contact of video cables

Exclude

Camera is damaged

Replace

Normal self-check and

image but out of control

Wrong contact of control

signal

Correct

Address configuration

wrong

Choose new address and

power up

Protocol or Baud rate

configuration wrong

Adjust Protocol, baud rate to

match controller and power up

Unstable image

Bad contact of video cable

Exclude

This manual is related to the following products: