6.2 Supported diagnostic messages

In the following the different diagnostic
messages are described in detail.

6.2.1 Extended diagnostics header

Byte 7 contains the length of the extended
diagnostics (including header itself).

6.2.2 Operating status

Diagnostic byte 9 contains certain parameters
(set in the system configuration).

Bit Definition

0

1

0

Direction of rotation CW

CC
W

1

Class 2 functionality

Off

On

2

Diagnostic routine

Off

On

3

Scaling function

Off

On

6.2.3 Encoder type

Diagnostic byte 10 contains the encoder
version (singleturn or multiturn).

Byte 10

Definition

0

Singleturn encoder

1

Multiturn encoder

6.2.4 Singleturn resolution

Diagnostic bytes 11-14 contain the real
(physical) resolution per revolution of the
encoder.

6.2.5 Number of revolutions

Diagnostic bytes 15 and 16 contain the real
(physical) number of revolutions of the
encoder. Standard values are 1 for singeturn
and 65535 for multiturn devices.

6.2.6 Profile version

Diagnostic bytes 24 and 25 contain the profile
version of the encoder.

Byte

24

25

Bit

15 – 8

7 – 0

Data

2

7

- 2

0

2

7

- 2

0

Revision No.

Index

6.2.7 Software version

Diagnostic bytes 26 and 27 contain the
software version of the encoder.

Octet 26

27

Bit

15 – 8

7 - 0

Data

2

7

to 2

0

2

7

to 2

0

Revision No. Index

6.2.8 Operating time

The operating time of the encoder is not
supported set to FFFFFFFF hex

6.2.9 Zero offset

The zero offset is output in diagnostic bytes 32
to 35.

6.2.10 Programmed resolution

The programmed resolution per revolution is
output in diagnostic bytes 40 to 43. The value is
only valid if the scaling factor is based on the
parameter „resolution per revolution“ (cp.
5.1.3).

6.2.11 Programmed total resolution

The programmed, respectively calculated
total resolution is output in diagnostic bytes 44-
47.

6.2.12 Serial number

Diagnostic bytes 48-57 are intended for a serial
number.