Asante Technologies 5212 User Manual
Page 96

Status Monitoring and Statistics
Page 6-8
Counter
Description
RXAlignErrors
For the 10Mbps ports, the counter
records alignment errors.
For the 100Mbps ports, the counter
records the sum of alignment errors and
code errors (frames received with
rxerror signal).
RXOversize
The total number of packets received
that were longer than 1518 octets in
length (excluding framing bits, but
including FCS octes) and were otherwise
normal.
RXJabbers
The total number of packets received that
were longer than 1518 octets (excluding
framing bits, but including FCS octets),
and had either an FCS error or an
alignment error.
RXUndersize
The total number of packets received
with less than 64 octets (excluding
framing bits, but including FCS octets)
and were otherwise normal.
RXFragments
The total number of packets received
that were not an integral number of
octets in length or that had a bad FCS,
and were less than 64 octets in length
(excluding framing bits but including
FCS octets).
Pkt64
The total number of packets (including
error packets) received with 64 octets
(excluding framing bits, but including
FCS octets).
Pkt65-127
The total number of packets (including
error packets) received that were
between 65 and 127 octets in length
(excluding framing bits, but including
FCS octets).
book Page 8 Monday, March 2, 1998 4:27 PM