Setting Up For Management

Page 4-4

Out-of-Band

Management

Out-of-band network management allows you to configure,
manage, and monitor the IntraSwitch 5212 and each of its
ports. You can perform these functions via the following
method:

By attaching a terminal (or a terminal emulator)
to the IntraSwitch 5212’s Console port and
using the menu-driven Local Management
Interface.

Out-of-band network management is guaranteed even when the
in-band Ethernet network is down.

To access the IntraSwitch 5212’s Local Management Interface
using out-of-band management:

1

Connect a stand-alone terminal or a PC running
a terminal emulator directly to the IntraSwitch
5212’s Console port using a straight-through RS-
232 serial cable with a male connector.

Figure 4-2

Connecting to the Console port

2

Make sure both units are powered on.

If using a PC with a terminal emulator, make
sure it is configured with the following terminal
settings:

❏ Bits Per Second: 9600
❏ Data Bits: 8
❏ Parity: None
❏ Stop Bits: 1
❏ Flow Control: None

IntraSwitch 5212

Pwr

100 Mbps

Max Util

FDP / COL

Data

Link

10/100 1 2 3 4 5 6 7 8 9 10 11 12 MII

10/100

Console

RS-232

7

8

9

10

11

12

1

2

3

4

5

6

Stand-Alone Terminal
or PC Running Terminal
Emulation Software

Console Port
(female; requires a male connector)

Straight-Through
RS-232 Cable

book Page 4 Monday, March 2, 1998 4:27 PM