Configuring bootstrap parameters, Page 5-15 – Asante Technologies 5212 User Manual

Page 65

background image

Configuring Bootstrap Parameters

Page 5-15

Table 5-5 Bootstrap Parameter Settings

Setting

Description

Set Load Mode to Local

Executes the software image file from the

IntraSwitch 5212’s internal flash memory
(default setting).

Important! This is the IntraSwitch 5212’s

default setting.

Set Load Mode to

Remote

Loads a new software image file from a server

on the network.

Important! To use this option, you must

select BootP-TFTP or TFTP as the Boot
Mode.

Set Boot Mode to

Bootp-tftp

Sets the IntraSwitch 5212 to request an IP

address from a BootP server and download
the software image file through TFTP.

Important! To use this option, the

IntraSwitch 5212’s IP address must be set to
0.0.0.0 and the Load Mode must be set to
Remote.

Set Boot Mode to TFTP

Sets the IntraSwitch 5212 to only download

the software image file through TFTP (an IP
address is not requested).

Important! To use this option, the

IntraSwitch 5212 must already have an
assigned IP address and the Load Mode must
be set to Remote.

Set Boot Server IP

Address

Sets the IP address of the remote server

providing BootP/TFTP capabilities on your
network.

Set Boot File Name

Sets the software image file name and

network path.