5 power-on buffer, 13 ieee 488.1 interface messages, 1 get - group execute trigger – B&K Precision 4034 - Manual User Manual
Page 64: 2 dcl - device clear, 3 sdc - selected device clear, 4 llo - local lockout

64
Type:
Boolean
Examples:
:SYST:SEC ON
:SYST:SEC OFF
QUERY
Syntax:
:SYSTem:SECurity[:STATe]?
Response:
0 | 1
4.12.5.5 Power-on Buffer
This command is used to set the Power On Buffer setting. The instrument will power-on with the
setting stored in that buffer. Setting the value to 99 will result in the instrument powering up in the state
it was in before it was powered down.
COMMAND TYPE:
Setting or Query
SETTING
Syntax:
:SYSTem:POBuffer
Arguments:
Type:
Numeric
Range:
0 to 99
Rounding:
To integer value
Examples:
:SYST:POB 99
QUERY
Syntax:
:SYSTem:POBuffer? [
Response:
Power-on buffer in NR1 format.
4.13 IEEE 488.1 Interface Messages
4.13.1 GET - Group Execute Trigger
The GET is used by the pulse generator as a trigger when it is in either the TRIGGER, GATE or
BURST modes, with the trigger source set to BUS. It has the same effect as the *TRG common
command.
4.13.2 DCL - Device Clear
In response to the DCL, the PG does the following:
a)
Clears the input buffer and the output queue.
b)
Resets the Message Processing Functions.
4.13.3 SDC - Selected Device Clear
The response is as for the DCL message, when device is addressed to listen.
4.13.4 LLO - Local Lockout
Sending LLO when device is addressed to listen and controller is asserting the REN line will put the
device into "Remote with Lock out" state, locking out the front panel.