Arguments:
Type:
NRf
Units:
S (seconds), MS (milliseconds), US (microseconds), NS nanoseconds
Range:
100NS to 99.99S
Rounding:
To current resolution
Examples:
:TRIG:TIM 10E-6
:TRIG:TIM 500US
QUERY
Syntax:
:TRIGger:TIMer?
Examples:
:TRIG:TIM?
Response:
NR3
4.12.3.5 External Trigger Level
Used to control the trigger level of the external trigger.
COMMAND TYPE:
Setting or Query
SETTING
Syntax:
:TRIGger:LEVel
Arguments:
Type:
NRf
Units:
V, mV
Range:
–10V to +10V with 10mV resolution; 0V allowed
Rounding:
10mV
Examples:
:TRIG:LEV 5.56
QUERY
Syntax:
:TRIGger:LEVel?
Examples:
:TRIG:LEV?
Response:
NR3
4.12.3.6 Trigger Slope
This command is used to set the external trigger slope on which to trigger.
COMMAND TYPE:
Setting or Query
SETTING
Syntax:
:TRIGger:SLOPe
Arguments:
Type:
Character
Options:
POSitive
NEGative
Examples:
:TRIG:SLOP POS
:TRIG:SLOP NEG
QUERY
Syntax:
:TRIGger:SLOPe?
Examples:
:TRIG:SLOP?
Response: