beautypg.com

Frequency, Level, Signal acquisition – Atec Rohde-Schwarz_FSL Series User Manual

Page 35

background image

Version 09.00, December 2008

R&S

®

FSL Spectrum Analyzer

35

R&S

®

FSL-K93 WiMAX™/WiBro IEEE 802.16 OFDMA SISO

analysis (IEEE 802.16-2004, IEEE 802.16-2004/Cor1-2005,
IEEE 802.16e-2005, P802.16-Rev2/D3 WiMAX™ and WiBro)

The specifications of the R&S

®

FSL-K93 option are based on the data sheet of the R&S

®

FSL spectrum analyzer.

Specifications apply under the following conditions: 30 minutes warm-up time at ambient temperature, specified environmental
conditions met, calibration cycle adhered to, and all internal automatic adjustments performed. "Typical values" are designated with
the abbreviation "typ." These values are verified during the final test but are not assured by Rohde & Schwarz. "Nominal values" are
design parameters that are not assured by Rohde & Schwarz. These values are verified during product development but are not
specifically tested during production.

Frequency

RF input

R&S

®

FSL3 50

MHz

17

to 3 GHz

R&S

®

FSL6 50

MHz

17

to 6 GHz

Frequency range

R&S

®

FSL18 50

MHz

17

to 18 GHz

model

serial number or lower

R&S

®

FSL3

18

100703

R&S

®

FSL6

18

100604

R&S

®

FSL3 100945

R&S

®

FSL6 100759

1.44 MHz to 20 MHz

model

serial number or higher

R&S

®

FSL3

18

100704

R&S

®

FSL6

18

100605

R&S

®

FSL3 100946

R&S

®

FSL6 100760

1.44 MHz to 32 MHz

Sampling rate F

s

R&S

®

FSL18

1.44 MHz to 32 MHz

Level

Level range

RF input

60 dBm to +30 dBm
auto

Level setting

manual

Signal acquisition

IEEE 802.16-2004 OFDMA SISO
IEEE 802.16-2004/Cor1-2005 OFDMA
SISO
IEEE 802.16e-2005 OFDMA SISO
P802.16-Rev2/D3 OFDMA SISO

Supported standards

IEEE 802.16e-2005 based WiBro

Capture length

24 µs to 15.6 ms

Gate length

24 µs to capture length

Number of analyzed subframes

1 to 10922 subframes

EVM versus symbol, burst summary list,
constellation versus symbol, bit stream

capture length

19

FFT spectrum, CCDF

capture length or gate length

Result length

result summary, power versus time, EVM
versus carrier, spectrum flatness,
spectrum flatness difference, group delay,
frequency error versus sample, phase
error versus sample

capture length

19

or

1 to 10922 subframes

Frame length

2 ms to 15 ms

spectrum mask

2.5 ms to 16000 s, auto

Sweep time

adjacent channel power ratio (ACPR)

10 ms to 16000 s

Sweep count

1 to 32767

Trigger modes

RF input

free run, external, power

17

5 MHz to 50 MHz with restricted functionality depending on bandwidth (power trigger, auto level, IF overload).

18

With tracking generator.

19

Max. 100 zones/subframes per capture buffer, max. 1000 bursts per capture buffer.