beautypg.com

Fsl-k84 1xev-do base station measurement, Frequency, Level – Atec Rohde-Schwarz_FSL Series User Manual

Page 25: Signal acquisition, Measurement parameters, Result display

background image

Version 09.00, December 2008

R&S

®

FSL Spectrum Analyzer

25

R&S

®

FSL-K84 1xEV-DO base station measurement

Frequency

RF input

R&S

®

FSL3

3 MHz to 3 GHz

R&S

®

FSL6

3 MHz to 6 GHz

3

Frequency range

R&S

®

FSL18

3 MHz to 18 GHz

3

Level

Level range

RF input

60 dBm to +30 dBm

Level setting

auto, manual

Signal acquisition

Supported standards

1xEV-DO Revision 0
1xEV-DO Revision A

Capture length

2 to 12 power control groups

Sweep time

spectrum mask
adjacent channel power ratio (ACPR)

max. 16000 s, auto
max. 16000 s

Sweep count

1 to 32767

Trigger modes

RF input

free run, external

Measurement parameters

predefined bands

band classes 0 to 17,

Frequency band

unspecified

limits can be user-specified

Link mode

downlink (DL)

Modulation detection

automatic detection of BPSK, QPSK,
8PSK, 16QAM

Predefined channel table

code domain analyzer

The predefined channel table allows the
complete channel setup of the user signal
for the code domain analyzer.

standard

in line with band classes 0 to 17

Spectrum emission mask

user

The spectrum emission mask
measurement is performed based on
either a manual user setting or a user-
specified XML file.

Result display

General results

clear write, max. hold, min. hold, average,
view

global results over all slots:
carrier frequency error (reading in Hz and
ppm), chip rate error, trigger to frame, rho
of pilot channel over all slots, rho of MAC
channel over all slots, rho of data channel
over all slots, rho overall-1 (halfslot
boundary), rho overall-2 (quarterslot
boundary)

results for selected slot:
total power, pilot power, MAC power, data
power, preamble power, rho, composite
EVM

3

All the values specified for

R&S

®

FSL-K84

in this data sheet are valid up to 3 GHz.