Installation
Installation
¡This pump is not designed to explosion-proof spec-
ifications. It cannot be used in explosion-proof
areas, and in explosive/ignitable atmospheres.
¡Install the pump in locations out of reach of per-
sonnel other than an administrator.
¡If you have forgotten to open a valve or foreign
objects are blocking the piping on the discharge-
side of the pump, an excessive pressure rise that
will exceed the pump's specification ranges may
occur, liquid may spray out or piping may be dam-
aged, which is dangerous.
!
WARNING
• Avoid installing the pump in the direct sunlight. Also,
prevent it from being exposed to wind and rain.
Though this pump is designed for outdoor use (IP65),
temperature sometimes builds up on metal parts due
to direct sunlight, plastic parts sometimes become
impaired due to UV rays, and scratches and rusting
sometimes occurs due to sand, dirt and rainfall. To
extend the service life of the pump when it is installed
outdoors, we recommend installing an awning or
shade cover.
• Install the pump in a location that is well-ventilated
during summer, and where chemicals will not freeze
in winter.
• Leave enough space to allow easy access for main-
tenance and inspection work.
• Maintenance space.
• Install the pump on a flat horizontal surface and fix it
securely to prevent it from vibrating during operation.
If the pump is installed on an inclined surface, the
pump may not be able to discharge properly or at all.
Use the four pump fixing bolts (supplied) to secure the
pump in position.
Installation Site
Position of Installation Bolts
5m
and over
5m
and
over
pump space
5m
and
over
7m
and over
165
145
110
32
9
170
38