Discharge performance of high-viscosity liquids, Specifications – Pump Solutions Group PZiG Series User Manual
Page 40
![background image](/manuals/313402/40/background.png)
39
Specifications
■Length of Discharge-side Piping
and Discharge Volume
The graph below shows the relationship between piping
length and discharge volume. Installing a damper
lessens piping resistance and allows the length of the
piping to be extended.
PZiG-1300-VTCE-12x18-W-S
Conditions: Room temperature, clean water
Piping length, discharge volume,
and effect of damper
1200
1220
1240
1260
1280
1300
1320
1340
1360
1380
1400
0
2
4
6
8
10
12
Piping length (m)
Discharge volume [mL/min]
with a
damper
without a
damper
* Discharge pressure 0.20 MPa
■Discharge Performance of
High-viscosity Liquids
When a fast stroke speed is set for transferring high-
viscosity liquids, piping resistance on the suction side
may cause the amount of sucked in liquid to be
reduced.
PZiG-300-VTCF-VP20-V-S
Conditions: Room temperature
0
50
100
150
200
250
300
350
400
0
100
200
300
Strokes (spm)
Discharge volume [mL/min]
Polymer
coagulants
(1000mPa . S)
Clean water
* Discharge pressure 1.0 MPa
05-45_PZiG Series(2)English 06.8.4 9:39 AM y [ W 39