Electrical wiring, Installation, Warning – Pump Solutions Group PZiG Series User Manual
Page 11: Caution, Standalone operation, Important
10
Installation
Electrical Wiring
¡Do not operate this pump with wet hands. Doing so
might result in electric shock.
¡Do not turn the power ON during electrical wiring.
Attach a "Work In Progress" label to the power
switch.
¡Reliably ground the earth terminal. Failure to do so
might result in electric shock. Be sure to install a
current leakage breaker.
¡Do not disassemble the body or circuits.
!
WARNING
¡Electrical wiring must be performed by personnel
such as an electrician having specialist knowledge.
¡Check the power voltage before wiring. Do not wire
a power supply outside of the rated voltage range.
¡Be sure to ground the earth lead (green) when
wiring to prevent electric shock.
!
CAUTION
●
When operating the pump interlocked
with a transfer pump
Wiring Example
●
Standalone operation
Transfer
pump
P
ELB
NFB
MC1 TH
U
V
W
E
CP (*1)
MC2
NFB
Ground
Green
PZiG
pump
PZiG
pump
Operation signal
CS1
CS2
Auto
OFF
Manual
Auto
OFF
Manual
X
X
MC
1
MC
2
PL
PL
ELB
NFB
MC
1~2
TH
CP
CS
1~2
X
PL
: Current leakage breaker
: No-fuse breaker
: Electromagnetic contactor
: Thermal relay
: Circuit protector
: Changeover switch
: Auxiliary relay
: Operation indicator
Transfe
pump
TH
Power supply
AC200V
3
ELB
CP
Power supply
AC100~240V
Ground
PZiG
pump
Green
¡A circuit protector (CP) is ideal as an overcur-
rent protection device on this pump from the
aspects of operating time and shutoff current
characteristics. (5 A medium-speed type)
¡The circuit protector indicated as a recom-
mended protective device can also be used as
a power supply switch, which simplifies wiring.
¡A thermal relay for a motor is unsuitable for
protection of this pump from the aspect of char-
acteristics.
NOTE
¡Be sure to use a commercial power supply
(power supplied from an electric power compa-
ny) as the power supply.
¡Power supplies that cannot be used:
1.Power supply equipped with an AC power
regulator
2.Power supply on the output side of the invert-
er
¡Do not take power in from the same terminal as
an induction motor (e.g. transfer pump).
A high voltage may be generated, for example,
when the power is turned OFF and damages
the pump.
IMPORTANT
P
Transfer
pump,
etc.
U
V
W
Power
supply
PZiG pump